intermittent failure to heat air until total failure to heat

ApplianceGeneral Electric Dryer

ModelDDG7987R

Level of DifficultyEasy

Time to do repair15 - 30 mins

Age of ApplianceMore than 10 years

Tools

James From Asbury Park, NJ

Jun 08, 2012

Unplugged dryer. Removed access door from lower right front of dryer. Disconnected wiring harness to igniter. Couldn't reach retaining bolt with wrench or socket, but was able to spread igniter clip with fingers to be able to remove old igniter and then work new igniter into position without unbolting retaining clip - ultimately a tool-less operation that could have taken 5 minutes. Reconnect wiring harness and reconnect power. Test dryer then replace access cover.

Help other customers find the most helpful instructions.

Were these instructions helpful?

Diagrams and Parts List for this repair

Part PhotoPart DescriptionPriceAvailability

Gas Igniter

Part Number: PS268028

$22.62