Low water intake pressure error

ApplianceWhirlpool Washer

ModelGHW9400PW0

Level of DifficultyEasy

Time to do repair15 - 30 mins

Age of Appliance1 - 4 years

Tools Pliers
Socket set

John From Rye Brook, NY

Jun 29, 2011

6 out of 6 people found this instruction helpful

Serviceman had previously replaced the hot and cold inlet valves, but the low pressure error persisted. Rather than cough up another $130 for the serviceman to return, plus parts and time, I decided to order the replacement flowmeter from PartSelect.

Unplug power and turn off water. Top of machine comes off by removing three screws at top rear; use socket, spanner or T20 driver. Unplug electric sensor from flowmeter. Old unit is removed, and new one connected to water line by squeezing spring-clips with a pair of flat nose pliers. Reconnect electric sensor.

Great move, easy, and saved myself the thick end of $200.

Help other customers find the most helpful instructions.

Were these instructions helpful?

Diagrams and Parts List for this repair

Part PhotoPart DescriptionPriceAvailability

Flowmeter

Part Number: PS1490923

$37.52
In Stock