8" Burner element intermittent, unable to control.

ApplianceWhirlpool Range

ModelRF199LXHQ

Level of DifficultyReally easy

Time to do repairLess than 15 mins

Age of Appliance5 - 10 years

Tools Screw drivers

Charles From Enfield, CT

Apr 21, 2011

10 out of 12 people found this instruction helpful

Easy.... UNPLUG THE STOVE FROM THE 240 VOLT OUTLET & READ THE DIRECTIONS THAT COME WITH THE NEW PART !! Removed upper rear cover panel 8 screws & removed panel, removed knob & 2 screws from front of control unit (on the control panel), pulled the control off the panel from the rear, removed the wires on the rear of control & connected them to the SAME terminals on the new control (one at a time). Then installed the new control by reversing the procedure above. Took about 15 minutes. IMPORTANT HINTS: 1) Make sure you save the little black pressure clip from the control stem on the new control, if you need to break-off the little part at the end of the stem. You will need to push the clip back into the recess on the new stem, in order for the knob to stay on the stem when you put it back on; 2) Use a needle-nose plier to pull the wire clips from the old control terminals & push them onto the same terminals on the new control, one at a time so the wiring is correct.

Help other customers find the most helpful instructions.

Were these instructions helpful?

Diagrams and Parts List for this repair

Part PhotoPart DescriptionPriceAvailability

Surface Burner Element Switch - 8"

Part Number: PS336989

$40.67
In Stock