Burner had no temperature control other that full on.

ApplianceJenn-Air Range

Model

Level of DifficultyEasy

Time to do repair15 - 30 mins

Age of ApplianceMore than 10 years

Tools Pliers
Screw drivers

Eric From North Andover, MA

Nov 16, 2007

27 out of 35 people found this instruction helpful

Locate and open appropriate breaker to kill power to the range. (very important if you intend to see tomorrow).

Pull off the control knob.

Remove 2 screws that hold in control pannel.

Lift out the control pannel to the extent that the wires will let you. (2-3 inches)

Remove the nut that holds the switch/controller in the pannel.

Remove the wires one at a time and reconnect them to the new switch. Make sure to connect them the same way on the new switch.

Re-install the switch in the pannel.

Re-install the pannel in the stove.

Close breaker and test burner contol.