freezer coil frozen solid

ApplianceGeneral Electric Refrigerator

Model

Level of DifficultyEasy

Time to do repair30 - 60 mins

Age of Appliance1 - 4 years

Tools Nutdriver
Screw drivers

David From Greenfield, IN

Nov 01, 2007

17 out of 26 people found this instruction helpful

Removed the back cover of freezer to acess the coil. Turned the timer to defrost and checked the voltage across the heater. Didn't have any. Stayed on the common side of heater and measured on both sides of thermostat and one side didn't have any voltage. Shorted the thermostat wires together and heater started working.

Help other customers find the most helpful instructions.

Were these instructions helpful?

Diagrams and Parts List for this repair

Part PhotoPart DescriptionPriceAvailability

Defrost Thermostat

Part Number: PS303434

$14.93
In Stock