Door closing cams were both broken

ApplianceGeneral Electric Refrigerator

Model

Level of DifficultyEasy

Time to do repair15 - 30 mins

Age of ApplianceMore than 10 years

Tools Screw drivers
Socket set

Michael From Portland, OR

Nov 23, 2009

0 out of 1 people found this instruction helpful

Remove screw at hinge cover, top of door.
Remove two screw/nuts at hinge and remove hinge while holding door in place.
Lift door off of lower hinge
remove two nut/screws at bottom of door and replace closing cam. Be sure the pivot pin hole in the cam is lined up with the hole in door.

Next drill out rivet holding cam to lower hinge on the refer. Install cam with a pan head screw and nut (to replace rivet). It will help if you remove the plastic grille cover at the bottom of the frige.

Set door back on the lower pin and shut so the the magnetic strip holds the door in place. Re-install the upper hinge loosely. Adjust the door for an even gap and tighten the screw/nuts. Re-install the cover.

A very easy fix.

Help other customers find the most helpful instructions.

Were these instructions helpful?