leak on bottom of refrigerator.

ApplianceGeneral Electric Refrigerator

Model

Level of DifficultyA Bit Difficult

Time to do repair30 - 60 mins

Age of Appliance5 - 10 years

Tools Wrench set
Pliers
Nutdriver

James From Nashville, TN

Nov 03, 2009

1 out of 3 people found this instruction helpful

removed back cover covering compressor and condenseing fan ,located vavle system,there are two the one leaking was the single solenoid vavle .To remove ,remove screws holding the double solenoid cause the single one is mounted to the double one ,once that done undo the water lines under the double vavle and pull out vavles .The bracket holding the single is connected to the double one by two screws,then undo the water lines ,then the wire connecter,then the reverse of what you do with the new one.

Help other customers find the most helpful instructions.

Were these instructions helpful?

Diagrams and Parts List for this repair

Part PhotoPart DescriptionPriceAvailability

Single Solenoid Water Inlet Valve

Part Number: PS304349

$64.50
In Stock

Water Inlet Valve - 120V 60Hz

Part Number: PS1990907

$21.07
In Stock