Models > RFS12SW2A

RFS12SW2A - Overview

Models starting with RFS12SW2A

Keep searches simple, eg. "belt" or "pump".
Black Sleeve Diode – Part Number: WPR9800486
Black Sleeve Diode
★★★★★
★★★★★
(3)
PartSelect #: PS11747959
Manufacturer #: WPR9800486
In your microwave, the diode allows current to flow one-way only, converting alternating current to direct current. If you notice that your microwave does not heat properly, you may need to replace th...
$31.50
  In Stock
Order within the next 6 hrs and your part ships today!
Screw,Tapping – Part Number: 1TTL0402818
Screw,Tapping
★★★★★
★★★★★
(1)
PartSelect #: PS3517555
Manufacturer #: 1TTL0402818
$8.17
  In Stock
Order within the next 6 hrs and your part ships today!
Magnetron – Part Number: 6324W1A001L
Magnetron
★★★★★
★★★★★
(6)
PartSelect #: PS3529034
Manufacturer #: 6324W1A001L
This magnetron in your microwave creates the radiation needed for cooking or warming your food. It is located inside the main cavity, typically near the transformer or waveguide. When the magnetron be...
$180.80
  In Stock
Order within the next 6 hrs and your part ships today!
MAGNETRON – Part Number: W10859575
MAGNETRON
★★★★★
★★★★★
(1)
PartSelect #: PS11731447
Manufacturer #: W10859575
This part is used to generate microwave energy/heat.
$259.57
  In Stock
Order within the next 6 hrs and your part ships today!
Screw,Tapping – Part Number: 1TTL0402422
Screw,Tapping
PartSelect #: PS3517550
Manufacturer #: 1TTL0402422
$8.57
  Special Order
Screw,Taptite – Part Number: 1SBF0402418
Screw,Taptite
PartSelect #: PS3517460
Manufacturer #: 1SBF0402418
$8.17
  In Stock
Order within the next 6 hrs and your part ships today!
Screw,Tapping – Part Number: 1TTL0402418
Screw,Tapping
PartSelect #: PS3517549
Manufacturer #: 1TTL0402418
$7.36
  In Stock
Order within the next 6 hrs and your part ships today!
GREASE SHIELD – Part Number: 53001556
GREASE SHIELD
PartSelect #: PS909630
Manufacturer #: 53001556
  No Longer Available
USE ACP 53001601 – Part Number: 53001601
USE ACP 53001601
PartSelect #: PS909675
Manufacturer #: 53001601
  No Longer Available
USE ACP R0654183 – Part Number: R0654183
USE ACP R0654183
PartSelect #: PS199166
Manufacturer #: R0654183
  No Longer Available
USE ACP M0805106 – Part Number: M0805106
USE ACP M0805106
PartSelect #: PS179709
Manufacturer #: M0805106
  No Longer Available
THERMAL CUT OUT- MAGN – Part Number: 53001560
THERMAL CUT OUT- MAGN
PartSelect #: PS909634
Manufacturer #: 53001560
  No Longer Available

Common Symptoms of models starting with RFS12SW2A

[Viewing 1 of 1]
No heat
Fixed by
these parts
Fixing Fixing Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
loud buzzing noise
The repair went well...I am so glad that I read this info before buying a new microwave....it saved me lots of money. I did have a repair man come and look at it and he told me to buy a new one but it cost alot of money when it wasn't necessary. I did the repair and I was very proud of myself.
Three men watched a woman fix this and it was no problem...they were impressed also....
Parts Used:
MAGNETRON
  • Sandra from coto de caza, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
56 of 100 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no heat
I looked up the #1 reason for no heat for my microwave on the site , and using my model number found that 92% of the time it was the Black Sleeve Diode. Ordered the $15 part, and installed it within 30 minutes. Most of the time was used for removing the built in microwave and removing the cover. Replaced the diode by finding it on the diagram that I printed from this site (free). Very relieved that we don't need to have our custom cabinetry re-sized to accommodate a new microwave. Thank you!
Parts Used:
Black Sleeve Diode
  • Lisa from PARADISE, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
28 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Magnitron failed
Over the stove microwave installed in top cabinet row.
1. Unplug device.
2. Two people to remove from wall/cabinet (remove two, large, top mounting screws and rotate entire microwave down and off the wall mount). Should be some wood spacers between top of device and bottom of cabinet.
3. Remove screws from sheet metal cover.
4. Remove one screw holding blowers in place and rotate out of the way, in order to gain access to 2 of 5 screws that hold the magnetron in place.
5. Unplug magnetron and remove the 5 screws.
6. Drop in new magnetron and re-assemble microwave in reverse order (steps 5-3).
7. Two people restore micro to wall/cabinet. Replace wood spacers, re-install two, large mounting screws (finger-tight). Test device. Secure the two large screws.
Parts Used:
Magnetron
  • Joseph from WILTON, NH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?